Packages
Math
Includes many mathematical and logical functions.
DuctNet
Static state package, used for duct network calculation.
Refrigeration
Static state package, for refrigeration system design and optimization. Detail
ECSOptim
Static state package, for airplane Environmental Control System(ECS, or A/C system) design and optimization.
HXFinPlate
Static state package, for Fin-Plate style heat exchangers design and simulation.
General
Dynamic state package, general components for dynamic simulation.
Interactive
Dynamic state package, interactive components for dynamic simulation.
Other software
Psychrometric Chart + Duct Calculator
This psychrometric chart tool is precise, powerful and easy to use. Detail
Contact
Phone: +1 347 981 9032

Static system calculation/simulation

Static system simulation

Static system simulation is used to find system static characteristic when system component performance is known.

Static system design

Static system design is the reversed process of static system simulation. In this situation, the system performance is known or is required, the calculation is processed to find the component size or parameters for selecting.

By using static component design model or design state model, the component and the system design is completed at the same time.


Samples

Static system simulation

Duct simulation without considering interplay between local resistance.

Select "Open" from menu or on toolbar, select software install directory\samples\ductnet.ssmodel, this model has been created, open as follow window:


This duct network can be treat as end of room air distribution. In this project, the input parameter is air duct outlet pressure, the output data is system inlet pressure. So back pressure of orifice at duct end can be inputed as room pressure.

Select static calculation from menu of on toolbar, the calculation is finished soon and the following result window pops up:


The results include data of input and port. Click here to openĄŁ

Static system design

Single stage refrigeration system design

Select "Open" from menu or on toolbar, select software install directory\samples\Ref1_5.ssmodel, this model has been created, open as follow window:


In this system, the cooling air parameter of condenser is inputed, the component AirOutlet after FanDesign is used to calculate fan air discharge loss. When pressure in the fan ducting is balanced, the calculated fan pressure difference is the real fan pressure head; FanDesign is design state component which is used to select fan; The needed fan can be selected by its flow and pressure head.

The ventilating fan component also use FanDesign for fan selecting, which pressure calculating is as same as condenser fan.

EvaporatorDesign component model will calculate the condensed water quantity of cooled air; WaterSeparator model is used to evaluate air parameters after removing free water.

CondenserDesign and EvaporatorDesign is for design, the pressure or phase change temperature is inputed, so the pressure at each refrigerant circuit node is known. After system iteration balanced, the calculated size of the two component can be used for producing. The CompressorDesign is design state component, which calculation result is used for compressor selecting.

As system design, we need to check final result. If the component size is not suitable for producing, we can change data inputs to regulate.

All component input data is included in calculation result, please open it at the end of this page.

Select "Static calculation" from menu or on toolbar, the calculation is finished soon and result text out window is as follow:


The results include component input data and each component port data, click here to open.